Bornheim, A. and Gataullin, M. and Litvine, V. and Ma, Y. and Newman , H. B. and Orimoto, T. and Rogan, C. and Timciuk, V. and Veverka, J. and Yang, Y. and Zhang, L. Y. and Zhu, K. and Zhu, R. Y. (2010) Radiation hardness qualification of PbWO_4 scintillation crystals for the CMS Electromagnetic Calorimeter. Journal of Instrumentation, 5 . Art. No. P03010. ISSN 1748-0221 http://resolver.caltech.edu/CaltechAUTHORS:20110125-122043736
|
PDF
- Published Version
Creative Commons Attribution. 753Kb |
Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20110125-122043736
Abstract
Ensuring the radiation hardness of PbWO_4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
| Item Type: | Article |
|---|---|
| Additional Information: | © 2010 IOP Publishing Ltd and SISSA. Received: December 24, 2009; accepted: February 5, 2010; published: March 25, 2010. |
| Subject Keywords: | Radiation damage to detector materials (solid state); Calorimeters |
| Classification Code: | PACS: 29.40.Mc; 61.72.J; 29.40.Vj; 61.82.Ms; 61.80.Ed |
| Record Number: | CaltechAUTHORS:20110125-122043736 |
| Persistent URL: | http://resolver.caltech.edu/CaltechAUTHORS:20110125-122043736 |
| Related URLs: | |
| Official Citation: | The CMS Electromagnetic Calorimeter Group et al 2010 JINST 5 P03010 doi: 10.1088/1748-0221/5/03/P03010 |
| Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. |
| ID Code: | 21881 |
| Collection: | CaltechAUTHORS |
| Deposited By: | Jason Perez |
| Deposited On: | 26 Jan 2011 22:30 |
| Last Modified: | 26 Dec 2012 12:52 |
Repository Staff Only: item control page