CaltechAUTHORS
  A Caltech Library Service

A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses

Pang, Changlin and Cham, Jorge G. and Nenadic, Zoran and Musallam, Sam and Tai, Yu-Chong and Burdick, Joel W. and Andersen , Richard A. (2005) A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses. In: 2005 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Proceedings of Annual International Conference of the IEEE Engineering in Medicine and Biology Society . IEEE , Piscataway, NJ, pp. 7114-7117. ISBN 0-7803-8740-6 http://resolver.caltech.edu/CaltechAUTHORS:20110822-090337561

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20110822-090337561

Abstract

This work presents a new multi-site probe array applied with parylene technology, used for neural prostheses to record high-level cognitive neural signals. Instead of inorganic materials (e.g. silicon dioxide, silicon nitride), the electrodes and conduction traces on probes are insulated by parylene, which is a polymer material with high electrical resistivity, mechanical flexibility, biocompatibility and easy deposition process. As a result, the probes exhibit better electrical and mechanical properties. The all dry process is demonstrated to fabricate these probe arrays with monolithically integrated parylene flexible cables using double-side-polished (DSP) wafers. With the parylene flexible cables, the probes can be easily assembled to a high density 3-D array for chronic implantation.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1109/IEMBS.2005.1616146 DOIUNSPECIFIED
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=1616146PublisherUNSPECIFIED
Additional Information:© 2005 IEEE. Manuscript received April 9, 2005. Date of Current Version: 10 April 2006. This work was supported by the National Institutes of Health. We would like to thank Mr. Trevor Roper for assistance with fabrication and the members of the Anderson lab at Caltech for help on vivo testing.
Funders:
Funding AgencyGrant Number
NIHUNSPECIFIED
Other Numbering System:
Other Numbering System NameOther Numbering System ID
INSPEC Accession Number9239663
Record Number:CaltechAUTHORS:20110822-090337561
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:20110822-090337561
Official Citation:Changlin Pang; J.G. Cham; Z. Nenadic; S. Musallam; Yu-Chong Tai; J.W. Burdick; R.A. Andersen; , "A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses," Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the , vol., no., pp.7114-7117, 2005 doi: 10.1109/IEMBS.2005.1616146 URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1616146&isnumber=33900
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:24966
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:22 Aug 2011 18:05
Last Modified:22 Aug 2011 18:05