Keller, K. H. and Friedlander, S. K. (1966) Diffusivity Measurements of Human Methemoglobin. Journal of General Physiology, 49 (4). pp. 681-687. ISSN 0022-1295 http://resolver.caltech.edu/CaltechAUTHORS:20120921-074514645
|
PDF
- Published Version
Creative Commons Attribution Non-commercial Share Alike. 287Kb |
Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20120921-074514645
Abstract
Experimental measurements of the diffusion coefficient of human methemoglobin were made at 25°C with a modified Stokes diaphragm diffusion cell. A Millipore filter was used in place of the ordinary fritted disc to facilitate rapid achievement of steady state in the diaphragm. Methemoglobin concentrations varied from approximately 5 g/100 ml to 30 g/100 ml. The diffusion coefficient in this range decreased from 7.5 x 10^(-7) cm^2/sec to 1.6 x 10^(-7) cm^2/sec.
| Item Type: | Article |
|---|---|
| Additional Information: | © 1966 Rockefeller University Press. Received for publication 21 May 1965. |
| Record Number: | CaltechAUTHORS:20120921-074514645 |
| Persistent URL: | http://resolver.caltech.edu/CaltechAUTHORS:20120921-074514645 |
| Related URLs: | |
| Official Citation: | Diffusivity Measurements of Human Methemoglobin K. H. Keller and S. K. Friedlander 49:681-687. doi:10.1085/jgp.49.4.681 |
| Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. |
| ID Code: | 34274 |
| Collection: | CaltechAUTHORS |
| Deposited By: | Ruth Sustaita |
| Deposited On: | 21 Sep 2012 16:47 |
| Last Modified: | 26 Dec 2012 16:13 |
Repository Staff Only: item control page