Chester, Marvin (1960) Evidence for a configurational emf in a conducting medium. Physical Review Letters, 5 (3). pp. 91-93. ISSN 0031-9007 http://resolver.caltech.edu/CaltechAUTHORS:CHEprl60
|
PDF
See Usage Policy. 509Kb |
Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:CHEprl60
Abstract
There is a pressure drop associated with an increase in the flow rate of a moving fluid. The venturi meter and the aspirator are familiar devices which derive from this phenomenon. This paper concerns itself with the detection of an analogous effect in the electron gas in a metal.
| Item Type: | Article |
|---|---|
| Additional Information: | ©1960 The American Physical Society. Received 2 May 1960; revised 14 July 1960. This research was supported jointly by the Alfred P. Sloan Foundation, Inc. and by the National Science Foundation. The author is indebted to Professor John R. Pellam for many helpful discussions and to Professor Richard P. Feynman for theoretical insights. |
| Record Number: | CaltechAUTHORS:CHEprl60 |
| Persistent URL: | http://resolver.caltech.edu/CaltechAUTHORS:CHEprl60 |
| Alternative URL: | http://dx.doi.org/10.1103/PhysRevLett.5.91 |
| Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. |
| ID Code: | 7490 |
| Collection: | CaltechAUTHORS |
| Deposited By: | Tony Diaz |
| Deposited On: | 28 Feb 2007 |
| Last Modified: | 26 Dec 2012 09:32 |
Repository Staff Only: item control page