NMR line narrowing by means of rotary spin echoes

Kessemeier, Horst and Rhim, Won-Kyu (1972) NMR line narrowing by means of rotary spin echoes. Physical Review B, 5 (3). pp. 761-768. ISSN 0556-2805. http://resolver.caltech.edu/CaltechAUTHORS:RHIprb72

[img]
Preview
PDF
See Usage Policy.

1103Kb

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:RHIprb72

Abstract

The dipolar broadened F19 resonance line in Teflon has been narrowed by irradiating the solid with strong continuous rf magnetic fields under magic-angle conditions. The transverse magnetization in the rotating frame lost under the action of rf and dc magnetic field inhomogeneities has been recovered by means of rotary spin echoes produced by dc magnetic field pulses. The variation of the longitudinal relaxation with direction and strength of the effective magnetic field in this compound has also been measured.


Item Type:Article
Additional Information:©1972 The American Physical Society. Received 4 August 1971. Work supported by the University of North Carolina Materials Research Center under Contract No. SD-100 from the Advanced Research Projects Agency.
Record Number:CaltechAUTHORS:RHIprb72
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:RHIprb72
Alternative URL:http://dx.doi.org/10.1103/PhysRevB.5.761
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:9413
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:20 Dec 2007
Last Modified:26 Dec 2012 09:48

Repository Staff Only: item control page