Paslaski, J. and Yariv, A. (1989) Differential photoconductive sampling with a resolution independent of carrier lifetime. Applied Physics Letters, 55 (17). pp. 1744-1746. ISSN 0003-6951. doi:10.1063/1.102205. https://resolver.caltech.edu/CaltechAUTHORS:PASapl89
![]()
|
PDF
See Usage Policy. 646kB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:PASapl89
Abstract
We present a novel approach to photoconductive sampling with a resolution which is virtually independent of the carrier lifetime and is governed solely by the circuit-limited gap charging time. Using photoconductors with a carrier lifetime of 150 ps, accurate measurement of a 65-ps-wide electrical signal is demonstrated and the actual resolution is believed to be 10 ps.
Item Type: | Article | ||||||
---|---|---|---|---|---|---|---|
Related URLs: |
| ||||||
Additional Information: | © 1989 American Institute of Physics. Received 26 June 1989; accepted 13 August 1989. This work was supported by the National Science Foundation and the Office of Naval Research. | ||||||
Issue or Number: | 17 | ||||||
DOI: | 10.1063/1.102205 | ||||||