Cryogenic spectrometer for measuring the far-IR to millimeter-wave absorptivity of cosmic analog dusts

Perera, T. A. and Zhang, R. and Liu, L.-J. and Schonert, R. K. and Phan, B. and Nam, S. M. and Dorsey, R. and Lopez, K. and North, K. C. and Ussery, C. and Roesner, R. A. (2021) Cryogenic spectrometer for measuring the far-IR to millimeter-wave absorptivity of cosmic analog dusts. Applied Optics, 60 (20). pp. 5880-5890. ISSN 1559-128X. doi:10.1364/ao.427831. https://resolver.caltech.edu/CaltechAUTHORS:20210803-172256346

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20210803-172256346

Abstract

We report on the design, construction, and performance of a custom apparatus built to measure the frequency- and temperature-dependent absorptivity of millimeter-wave light by cosmic analog dusts. We highlight the unique challenges faced as well as a few key innovations that are part of the instrument. Among those is an ultra-compact Fourier transform spectrometer. We have measured its effective frequency range and FWHM resolution to be 150–2100 GHz and ∼45GHz, respectively. Another innovation is a cold sample positioner whose temperature can be controlled within the range of 3.7–50 K. The use of a pulse-tube cryocooler results in a pulse-synchronous signal that dominates the detector (bolometer) signal. Methods used to address that challenge are also presented.


Item Type:Article
Related URLs:
URLURL TypeDescription
https://doi.org/10.1364/ao.427831DOIArticle
Additional Information:© 2021 Optical Society of America. Received 15 April 2021; revised 15 June 2021; accepted 16 June 2021; posted 17 June 2021 (Doc. ID 427831); published 8 July 2021. We thank D. J. Fixsen for valuable advice and guidance during the design and construction of the FTS. Funding: National Science Foundation (AST-1313261). Data Availability: Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request. The authors declare no conflicts of interest.
Funders:
Funding AgencyGrant Number
NSFAST-1313261
Issue or Number:20
DOI:10.1364/ao.427831
Record Number:CaltechAUTHORS:20210803-172256346
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20210803-172256346
Official Citation:T. A. Perera, R. Zhang, L.-J. Liu, R. K. Schonert, B. Phan, S. M. Nam, R. Dorsey, K. Lopez, K. C. North, C. Ussery, and R. A. Roesner, "Cryogenic spectrometer for measuring the far-IR to millimeter-wave absorptivity of cosmic analog dusts," Appl. Opt. 60, 5880-5890 (2021); DOI: 10.1364/ao.427831
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.