CaltechAUTHORS
  A Caltech Library Service

Streamline-Based Microfluidic Devices for Erythrocytes and Leukocytes Separation

Zheng, Siyang and Liu, Jing-Quan and Tai, Yu-Chong (2008) Streamline-Based Microfluidic Devices for Erythrocytes and Leukocytes Separation. Journal of Microelectromechanical Systems, 17 (4). pp. 1029-1038. ISSN 1057-7157. http://resolver.caltech.edu/CaltechAUTHORS:ZHEjmems08

[img]
Preview
PDF - Published Version
See Usage Policy.

862Kb

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:ZHEjmems08

Abstract

In this paper, we report two devices for the continuous size-based separation of particles, such as blood cells, which is an important step for on-chip blood preparation. Unlike previously demonstrated passive fluidic devices for particle separation, the local geometry of the bifurcated side channels was used as a design parameter. The design of the devices was based on 2-D fluidic simulation of a T-shaped model. This novel approach was proved to be effective in predicting device performance. The critical particle size for separation was clearly defined in the bifurcated region by simulation under the established theoretical framework. We validated the operation principle of the devices by separating 5- and 10-μm polystyrene beads. Human leukocytes were also successfully separated from erythrocytes with 97% efficiency. The separation region of the device had a small footprint for the separation of particles in micrometer range, which makes this device a good candidate to be integrated into a lab-on-a-chip system. The particles were collected in different exit channels after they were separated, which facilitated further sensing and processing. Similar to cross-flow filters, particles were separated perpendicular to the flow direction. The filtering effect was achieved with the collection zones established by the fluidic field. Clogging was minimized by designing the minimal channel width of the devices larger than the largest particle diameter. Solvent exchange could be accomplished for particles.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1109/JMEMS.2008.924274DOIArticle
http://ieeexplore.ieee.org/search/wrapper.jsp?arnumber=4570439PublisherArticle
ORCID:
AuthorORCID
Tai, Yu-Chong0000-0001-8529-106X
Additional Information:© Copyright 2008 IEEE. Reprinted with permission. Manuscript received August 5, 2007; revised February 8, 2008. First published July 18, 2008; last published August 1, 2008 (projected). This work was supported by the National Space Biomedical Research Institute through NASA NCC 9–58. Subject Editor A. Lee. The authors would like to thank all of the members of the Caltech Micromachining Group for their valuable assistance. Color versions of one or more of the figures in this paper are available online at http://ieeexplore.ieee.org.
Funders:
Funding AgencyGrant Number
NASANCC 9–58
Subject Keywords:Blood, microelectromechanical devices
Issue or Number:4
Record Number:CaltechAUTHORS:ZHEjmems08
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:ZHEjmems08
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:11588
Collection:CaltechAUTHORS
Deposited By: Archive Administrator
Deposited On:09 Sep 2008 01:38
Last Modified:20 Mar 2019 22:02

Repository Staff Only: item control page