CaltechAUTHORS
  A Caltech Library Service

Electrolysis-based Parylene Balloon Actuators for Movable Neural Probes

Pang, Changlin and Tai, Yu-Chong and Burdick, Joel W. and Andersen, Richard A. (2007) Electrolysis-based Parylene Balloon Actuators for Movable Neural Probes. In: 2007 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems. IEEE , Piscataway, NJ, pp. 913-916. ISBN 978-1-4244-0609-8 . https://resolver.caltech.edu/CaltechAUTHORS:20101104-104300160

[img]
Preview
PDF - Published Version
See Usage Policy.

3764Kb

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20101104-104300160

Abstract

In order to track a specific neuron and keep good sampling neural signals during chronic implantation, the neural probes are highly desired to have moving capability. This paper presents a novel electrolysis-based parylene balloon actuator fabricated with MEMS technology. The actuator is integrated with silicon probe to make it movable. A new fabrication technology has been developed to build a parylene balloon structure with silicon spring structure, electrolysis electrodes and electrolyte inside. By applying little current to electrolysis electrodes, high pressure is generated inside the parylene balloon by electrolysis. The spring structure is stretched with the parylene balloon expansion. Therefore the neural probe is moved by the actuation. The electrolysis actuator can generate large stain and pressure, requires modest electrical power and produces minimal heat. Due to the large volume expansion obtained via electrolysis, the small actuator can create a large force. The new electrolysis actuators for movable neural probes have been fabricated and validated.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1109/NEMS.2007.352166DOIArticle
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=4160469PublisherArticle
ORCID:
AuthorORCID
Tai, Yu-Chong0000-0001-8529-106X
Andersen, Richard A.0000-0002-7947-0472
Additional Information:© 2007 IEEE. Issue Date: 16-19 Jan. 2007; Date of Current Version: 23 April 2007. This project was funded by the National Institutes of Health (NIH). We wish to acknowledge Mr. Trevor Roper for assistance with fabrication.
Funders:
Funding AgencyGrant Number
NIHUNSPECIFIED
Subject Keywords:Electrolysis actuators; movable neural probes; parylene balloon actuators
Record Number:CaltechAUTHORS:20101104-104300160
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20101104-104300160
Official Citation:Changlin Pang; Yu-Chong Tai; Burdick, J.W.; Andersen, R.A.; , "Electrolysis-based Parylene Balloon Actuators for Movable Neural Probes," Nano/Micro Engineered and Molecular Systems, 2007. NEMS '07. 2nd IEEE International Conference on , vol., no., pp.913-916, 16-19 Jan. 2007 doi: 10.1109/NEMS.2007.352166 URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4160469&isnumber=4144525
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:20667
Collection:CaltechAUTHORS
Deposited By: Jason Perez
Deposited On:04 Nov 2010 20:28
Last Modified:03 Oct 2019 02:13

Repository Staff Only: item control page