Pang, Changlin and Musallam, Sam and Tai, Yu-Chong and Burdick, Joel W. and Andersen, Richard A. (2006) Novel Monolithic Silicon Probes with Flexible Parylene Cables for Neural Prostheses. In: 2006 International Conference on Microtechnologies in Medicine and Biology. IEEE , Piscataway, NJ, pp. 64-67. ISBN 978-1-4244-0337-0. https://resolver.caltech.edu/CaltechAUTHORS:20110428-151147967
![]()
|
PDF
- Published Version
See Usage Policy. 5MB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20110428-151147967
Abstract
This work presents the first parylene-insulated silicon probes, which are used for neural prostheses to record high-level cognitive neural signals. With parylene technology, our probes have several advantages compared with the current devices. First, instead of inorganic materials (e.g. SiO_2 and Si_3N_4), the electrodes and conduction traces on the probes are insulated by parylene, an easily-deposited polymer with mechanical flexibility and biocompatibility. As a result, the probes exhibit better electrical and mechanical properties. Second, flexible parylene cables are monolithically integrated with the probes, which arm the probes with very high flexibility to be easily assembled to a high density 3-D array and at the same time provide an ideal method to transmit neural signals through skull during chronic recording. The all dry fabrication process and an 8x2 probe array (64 electrodes) were demonstrated. The probes were successfully tested electrically and mechanically in rat and monkey cortex. Neural signals were properly recorded.
Item Type: | Book Section | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| |||||||||
ORCID: |
| |||||||||
Additional Information: | © 2006 IEEE. Issue Date: 9-12 May 2006. Date of Current Version: 30 July 2007. We would like to thank Mr. Trevor Roper for assistance with fabrication and the members of the Anderson lab at Caltech for help on vivo testing. | |||||||||
Subject Keywords: | neural probes; flexible parylene cables; neural prostheses | |||||||||
DOI: | 10.1109/MMB.2006.251491 | |||||||||
Record Number: | CaltechAUTHORS:20110428-151147967 | |||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20110428-151147967 | |||||||||
Official Citation: | Pang, C.; Musallam, S.; Yu-Chong Tai; Burdick, J.W.; Andersen, R.A.; , "Novel Monolithic Silicon Probes with Flexible Parylene Cables for Neural Prostheses," Microtechnologies in Medicine and Biology, 2006 International Conference on , vol., no., pp.64-67, 9-12 May 2006 doi: 10.1109/MMB.2006.251491 URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4281309&isnumber=4281284 | |||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | |||||||||