Trifunac, Mihailo D. and Udwadia, F. E. and Brady, Arthur Gerald (1971) High frequency errors and instrument corrections of strong-motion accelerograms. California Institute of Technology . (Unpublished) https://resolver.caltech.edu/CaltechEERL:1971.EERL-71-05
![]()
|
PDF (Adobe PDF (3 MB))
See Usage Policy. 2MB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechEERL:1971.EERL-71-05
Abstract
A study of high-frequency errors present in digitized accelerograms and an analysis of the distribution of unequally spaced, hand-digitized data indicates that the Fourier content of digitized accelerogram. data may be accurate up to about 25 cps. Two methods for accelerometer instrument correction are described: (1) a direct numerical differentiation of recorded accelerograms from which high-frequency digitization errors have been filtered out and (2) an ideal "mathematical accelerometer" with a natural frequency significantly higher than the natural frequency of the recording instrument. Although both methods give good results, the first one is recommended for the standard use.
Item Type: | Report or Paper (Technical Report) |
---|---|
Additional Information: | PB 205 369 |
Group: | Earthquake Engineering Research Laboratory |
Record Number: | CaltechEERL:1971.EERL-71-05 |
Persistent URL: | https://resolver.caltech.edu/CaltechEERL:1971.EERL-71-05 |
Usage Policy: | You are granted permission for individual, educational, research and non-commercial reproduction, distribution, display and performance of this work in any format. |
ID Code: | 26408 |
Collection: | CaltechEERL |
Deposited By: | Imported from CaltechEERL |
Deposited On: | 19 Feb 2008 |
Last Modified: | 03 Oct 2019 03:14 |