Au, S. K. and Yuen, K.-V. and Beck, J. L. (2000) Two-Stage System Identification Results for Benchmark Structure. In: Proceedings of the 14th Engineering Mechanics Conference. Dept. of Civil Engineering, University of Texas at Austin , Austin, TX. https://resolver.caltech.edu/CaltechAUTHORS:20120925-163435058
Full text is not posted in this repository.
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20120925-163435058
Abstract
This paper reports on Cases 1{3 of the benchmark study sponsored by the IASC-ASCE Task Group on Structural Health Monitoring which is defined in Johnson et al. [1]. These cases involve damage detection in the weak direction only of the test structure using a 12 DOF linear shear building model during the analysis. Cases 1 and 3 use data generated by broad-band excitation of the USC 12 DOF model at each floor and at the roof only, respectively. Case 2 uses data generated by broad-band excitation of the HKUST 120 DOF model at each floor.