Arndt, N. and Acosta, A. J. and Brennen, C. E. and Caughey, T. K. (1989) Experimental Investigation of Rotor-Stator Interaction in a Centrifugal Pump with Several Vaned Diffusers. In: ASME 1989 International Gas Turbine and Aeroengine Congress and Exposition. Vol.1. American Society of Mechanical Engineers , New York, NY, Art. No. V001T01A033. ISBN 978-0-7918-7913-9. https://resolver.caltech.edu/CaltechAUTHORS:ARNjt90
![]() |
PDF
- Published Version
See Usage Policy. 1MB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:ARNjt90
Abstract
This paper describes an experimental investigation of rotor-stator interaction in a centrifugal pump with several vaned diffusers. Steady and unsteady diffuser vane pressure measurements were made for a two-dimensional test impeller. Unsteady impeller blade pressure measurements were made for a second two-dimensional impeller with blade number and blade geometry identical to the two-dimensional impeller used for the diffuser vane pressure measurements. The experiments were conducted for different flow coefficients and differeent radial gaps between the impeller blade trailing edge and the diffuser vane leading edge (5 and 8 percent of the impeller discharge radius). The largest pressure fluctuations on the diffuser vanes and the impeller blades were found to be of the same order of magnitude as the total pressure rise across the pump. The largest pressure fluctuations on the diffuser vanes were observed to occur on the suction side of the vane near the vane leading edge, whereas on the impeller blades the largest fluctuations were observed to occur at the blade trailing edge. However, the dependence of the fluctuations on the flow coefficient was found to be different for te diffuser vanes and the impeller blades; on the vane suction side, the fluctuations were largest for the maximum flow coefficient and decreased with decreasing flow coefficient, whereas at the blade trailing edge, the fluctuations were smallest for the maximum flow coefficient and increased with decreasing flow coefficient. Increasing the number of the diffuser vanes resulted in a significant decrease of the impeller blade pressure fluctuations. The resulting lift on the diffuser vanes was computed from the vane pressure measurements; the magnitude of the fluctuating lift was found to be larger than the steady lift.
Item Type: | Book Section | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| |||||||||
Additional Information: | © 1989 by ASME. Contributed by the International Gas Turbine Institute and presented at the 34th International Gas Turbine and Aeroengine Congress and Exhibition, Toronto, Ontario, Canada, June 4-8, 1989. Manuscript received at ASME Headquarters January 13, 1989. Paper No. 89-GT-62. The authors are indebted to the NASA George Marshall Space Flight Center for the continued sponsorship of this research under contract NAS8-33108. | |||||||||
Funders: |
| |||||||||
Subject Keywords: | Diffusers, Rotors, Centrifugal pumps, Stators | |||||||||
DOI: | 10.1115/89-GT-62 | |||||||||
Record Number: | CaltechAUTHORS:ARNjt90 | |||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:ARNjt90 | |||||||||
Official Citation: | Arndt NN, Acosta AJ, Brennen CE, Caughey TK. Experimental Investigation of Rotor-Stator Interaction in a Centrifugal Pump With Several Vaned Diffusers. ASME. Turbo Expo: Power for Land, Sea, and Air, Volume 1: Turbomachinery ():V001T01A033. doi:10.1115/89-GT-62. | |||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | |||||||||
ID Code: | 35 | |||||||||
Collection: | CaltechAUTHORS | |||||||||
Deposited By: | Christopher Brennen | |||||||||
Deposited On: | 27 Aug 2004 | |||||||||
Last Modified: | 08 Nov 2021 19:00 |