CaltechAUTHORS
  A Caltech Library Service

Tests of CMS hadron forward calorimeter upgrade readout box prototype

Chatrchyan, S. and Apresyan, A. and Chen, Y. and Mott, A. and Spiropulu, M. (2012) Tests of CMS hadron forward calorimeter upgrade readout box prototype. Journal of Instrumentation, 7 (10). Art. No. P10015. ISSN 1748-0221. http://resolver.caltech.edu/CaltechAUTHORS:20130110-090234998

[img]
Preview
PDF - Published Version
Creative Commons Attribution.

1571Kb

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20130110-090234998

Abstract

A readout box prototype for the CMS Hadron Forward calorimeter upgrade was built and tested in the CERN H2 beamline. The prototype was designed to enable simultaneous tests of different readout options for the four anode upgrade PMTs, new front-end electronics design and new cabling. The response of the PMTs with different readout options was uniform and the background response was minimal. Multi-channel readout options further enhanced the background elimination. Passing all the electronic, mechanical and physics tests, the readout box proved to be capable of providing the forward hadron calorimeter operational requirements in the upgrade era.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1088/1748-0221/7/10/P10015DOIUNSPECIFIED
http://iopscience.iop.org/1748-0221/7/10/P10015/PublisherUNSPECIFIED
Additional Information:© 2012 CERN for the benefit of the CMS collaboration, published under the terms of the Creative Commons Attribution licence 3.0 by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation and DOI. This project was carried out with financial support from U.S. Department of Energy, U.S. National Science Foundation, RMKI-KFKI (Hungary), Russian Ministry of Education and Science, Russian State Committee for Atomic Energy, Scientific and Technical Research Council of Turkey (TUBITAK), Turkish Atomic Energy Agency (TAEK) and Bogazici University Research Fund. We thank the CERN PS and SPS accelerator personnel for their expert help in giving us excellent test beams that allowed us to carry our tests. The data analysis was performed at the University of Iowa CMS Tier-3 computing center.
Group:CMS@Caltech
Funders:
Funding AgencyGrant Number
Department of Energy (DOE)UNSPECIFIED
NSFUNSPECIFIED
RMKI-KFKI (Hungary)UNSPECIFIED
Russian Ministry of Education and ScienceUNSPECIFIED
Russian State Commottee for Atomic EnergyUNSPECIFIED
Scientific and Technical Research Council of Turkey (TUBITAK)UNSPECIFIED
Turkish Atomic Energy Agency (TAEK) UNSPECIFIED
Bogazici University Research FundUNSPECIFIED
Subject Keywords:Cherenkov detectors; Photon detectors for UV, visible and IR photons (vacuum); Calorimeters; Cherenkov and transition radiation
Classification Code:PACS: 29.40.Ka, 85.60.Ha, 85.60.Gz, 07.50.-e, 29.40.Vj
Record Number:CaltechAUTHORS:20130110-090234998
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:20130110-090234998
Official Citation:Tests of CMS hadron forward calorimeter upgrade readout box prototype CMS HCAL collaboration 2012 JINST 7 P10015
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:36292
Collection:CaltechAUTHORS
Deposited By: Ruth Sustaita
Deposited On:10 Jan 2013 17:40
Last Modified:25 Feb 2013 21:07

Repository Staff Only: item control page