CaltechAUTHORS
  A Caltech Library Service

Development of a multi-electrode array for spinal cord epidural stimulation to facilitate stepping and standing after a complete spinal cord injury in adult rats

Gad, Parag and Choe, Jaehoon and Nandra, Mandheerej Singh and Zhong, Hui and Roy, Roland R. and Tai, Yu-Chong and Edgerton, V. Reggie (2013) Development of a multi-electrode array for spinal cord epidural stimulation to facilitate stepping and standing after a complete spinal cord injury in adult rats. Journal of Neuroengineering and Rehabilitation, 10 (1). Art. No. 2. ISSN 1743-0003. PMCID PMC3599040. http://resolver.caltech.edu/CaltechAUTHORS:20130409-090318261

[img]
Preview
PDF - Published Version
Creative Commons Attribution.

1832Kb
[img] PDF - Erratum
Creative Commons Attribution.

258Kb
[img] Video (AVI) (Video 1) - Supplemental Material
Creative Commons Attribution.

1552Kb
[img] Video (AVI) (Video 2) - Supplemental Material
Creative Commons Attribution.

2660Kb
[img] Video (AVI) (Video 3) - Supplemental Material
Creative Commons Attribution.

1484Kb

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20130409-090318261

Abstract

Background: Stimulation of the spinal cord has been shown to have great potential for improving function after motor deficits caused by injury or pathological conditions. Using a wide range of animal models, many studies have shown that stimulation applied to the neural networks intrinsic to the spinal cord can result in a dramatic improvement of motor ability, even allowing an animal to step and stand after a complete spinal cord transection. Clinical use of this technology, however, has been slow to develop due to the invasive nature of the implantation procedures, the lack of versatility in conventional stimulation technology, and the difficulty of ascertaining specific sites of stimulation that would provide optimal amelioration of the motor deficits. Moreover, the development of tools available to control precise stimulation chronically via biocompatible electrodes has been limited. In this paper, we outline the development of this technology and its use in the spinal rat model, demonstrating the ability to identify and stimulate specific sites of the spinal cord to produce discrete motor behaviors in spinal rats using this array. Methods: We have designed a chronically implantable, rapidly switchable, high-density platinum based multi-electrode array that can be used to stimulate at 1–100 Hz and 1–10 V in both monopolar and bipolar configurations to examine the electrophysiological and behavioral effects of spinal cord epidural stimulation in complete spinal cord transected rats. Results: In this paper, we have demonstrated the effectiveness of using high-resolution stimulation parameters in the context of improving motor recovery after a spinal cord injury. We observed that rats whose hindlimbs were paralyzed can stand and step when specific sets of electrodes of the array are stimulated tonically (40 Hz). Distinct patterns of stepping and standing were produced by stimulation of different combinations of electrodes on the array located at specific spinal cord levels and by specific stimulation parameters, i.e., stimulation frequency and intensity, and cathode/anode orientation. The array also was used to assess functional connectivity between the cord dorsum to interneuronal circuits and specific motor pools via evoked potentials induced at 1 Hz stimulation in the absence of any anesthesia. Conclusions: Therefore the high density electrode array allows high spatial resolution and the ability to selectively activate different neural pathways within the lumbosacral region of the spinal cord to facilitate standing and stepping in adult spinal rats and provides the capability to evoke motor potentials and thus a means for assessing connectivity between sensory circuits and specific motor pools and muscles.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1186/1743-0003-10-2DOIArticle
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599040/PubMed CentralArticle
http://dx.doi.org/10.1186/s12984-015-0019-3DOIErratum
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4377014/PubMed CentralErratum
http://www.jneuroengrehab.com/content/10/1/2/additionalPublisherSupplemental Files
ORCID:
AuthorORCID
Tai, Yu-Chong0000-0001-8529-106X
Additional Information:© 2013 Gad et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Received: 15 February 2012 Accepted: 7 January 2013. Published: 21 January 2013. We would like to thank Maynor Herrera for providing excellent animal care and Sharon Zdunowski for technical assistance. This research was supported by the National Institute of Biomedical Imaging and Bioengineering R01EB007615. Authors’ contribution: PG and JC performed the experiments and analyzed the data. MN and YCT fabricated the implant. HZ and RRR performed the surgeries. PG, JC, RRR and VRE wrote the manuscript. All authors read and approved the final manuscript. The authors report no competing interest.
Funders:
Funding AgencyGrant Number
NIHR01EB007615
Subject Keywords:Spinal cord electrode array, Spinal cord injury, Epidural stimulation, Motor recovery
PubMed Central ID:PMC3599040
Record Number:CaltechAUTHORS:20130409-090318261
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:20130409-090318261
Official Citation:Gad et al.: Development of a multi-electrode array for spinal cord epidural stimulation to facilitate stepping and standing after a complete spinal cord injury in adult rats. Journal of NeuroEngineering and Rehabilitation 2013 10:2.
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:37817
Collection:CaltechAUTHORS
Deposited By: Ruth Sustaita
Deposited On:09 Apr 2013 16:27
Last Modified:14 Jun 2017 22:25

Repository Staff Only: item control page