CaltechAUTHORS
  A Caltech Library Service

Heterodyne interferometer with unequal path lengths

Kumar, Deepak and Bellan, Paul M. (2006) Heterodyne interferometer with unequal path lengths. Review of Scientific Instruments, 77 (8). Art. No. 083503. ISSN 0034-6748. http://resolver.caltech.edu/CaltechAUTHORS:KUMrsi06

[img]
Preview
PDF - Published Version
See Usage Policy.

307Kb
[img] PDF - Submitted Version
See Usage Policy.

5Mb

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:KUMrsi06

Abstract

Laser interferometry is an extensively used diagnostic for plasma experiments. Existing plasma interferometers are designed on the presumption that the scene and reference beam path lengths have to be equal, a requirement that is costly in both the number of optical components and the alignment complexity. It is shown here that having equal path lengths is not necessary, instead, what is required is that the path length difference be an even multiple of the laser cavity length. This assertion has been verified in a heterodyne laser interferometer that measures typical line-average densities of ~10^21/m^2 with an error of ~10^(19)/m^2.


Item Type:Article
Related URLs:
URLURL TypeDescription
https://doi.org/10.1063/1.2336769DOIArticle
https://arxiv.org/abs/physics/0608082arXivDiscussion Paper
ORCID:
AuthorORCID
Bellan, Paul M.0000-0002-0886-8782
Additional Information:© 2006 American Institute of Physics. (Received 22 May 2006; accepted 24 July 2006; published online 24 August 2006) Helpful discussions with Professor William B. Bridges and Professor Kerry Vahala on laser phase autocorrelation are gratefully acknowledged. We would also like to thank Dr. Heun-Jin Lee for his technical help in setting up the Michelson interferometer in Fig. 2 and Gunsu Yun for spectroscopic measurements. In addition, we would like to recognize the helpful initial guidance from Dr. Raymond P. Golingo, University of Washington, Seattle, in designing the heterodyne interferometer. This work was supported by USDOE Grant No. DE-FG02–04ER54755.
Funders:
Funding AgencyGrant Number
Department of Energy (DOE)DE-FG02–04ER54755
Subject Keywords:light interferometry; plasma diagnostics; plasma density; plasma toroidal confinement
Record Number:CaltechAUTHORS:KUMrsi06
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:KUMrsi06
Alternative URL:http://dx.doi.org/10.1063/1.2336769
Official Citation:Heterodyne interferometer with unequal path lengths Deepak Kumar and Paul M. Bellan Rev. Sci. Instrum. 77, 083503 (2006); http://dx.doi.org/10.1063/1.2336769
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:3806
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:18 Sep 2006
Last Modified:05 Apr 2019 20:34

Repository Staff Only: item control page