Principles of quantitative absorbance measurements in anisotropic crystals

Libowitzky, E. and Rossman, G. R. (1996) Principles of quantitative absorbance measurements in anisotropic crystals. Physics and Chemistry of Minerals, 23 (6). pp. 319-327. ISSN 0342-1791 . http://resolver.caltech.edu/CaltechAUTHORS:20130801-092700993

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20130801-092700993

Abstract

The accurate measurement of absorbance (A=-log T; T=I/I_0) in anisotropic materials like crystals is highly important for the determination of the concentration and orientation of the oscillator (absorber) under investigation. The absorbance in isotropic material is linearly dependent on the concentration of the absorber and on the thickness of the sample (A=ɛ·c·t). Measurement of absorbance in anisotropic media is more complicated, but it can be obtained from polarized spectra (i) on three random, but orthogonal sections of a crystal, or (ii) preferably on two orthogonal sections oriented parallel to each of two axes of the indicatrix ellipsoid. To compare among different crystal classes (including cubic symmetry) it is useful to convert measured absorbance values to one common basis (the total absorbance A_tot), wherein all absorbers are corrected as if they were aligned parallel to the E-vector of the incident light. The total absorption coefficient (a_tot=A_tot/t) is calculated by (i)a_tot = ∑^(3)_(i=1)(a_(max,i)+a_(min,i))/2, or by (ii) a_tot = a_x + a_y + a_z. Only in special circumstances will unpolarized measurements of absorbance provide data useful for quantitative studies of anisotropic material. The orientation of the absorber with respect to the axes of the indicatrix ellipsoid is calculated according to A_x/A_tot=cos^2 (x < absorber), and analogously for A_y and A_z. In this way, correct angles are obtained for all cases of symmetry. The extinction ratio of the polarizer (Pe=I_crossed/I_parallel) has considerable influence on the measured amplitude of absorption bands, especially in cases of strong anisotropic absorbance. However, if Pe is known, the true absorbance values can be calculated even with polarizers of low extinction ratio, according to A max=−log[(T_(max,obs)−0.5·Pe·T_(min,obs))/(1−0.5·Pe)], and similar for A_min. The theoretical approach is confirmed by measurements on calcite and topaz.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1007/BF00199497DOIArticle
http://link.springer.com/article/10.1007/BF00199497PublisherArticle
ORCID:
AuthorORCID
Rossman, G. R.0000-0002-4571-6884
Additional Information:© 1996 Springer-Verlag. Received August 10, 1995; Revised, accepted November 25, 1995. E.L. appreciates financial support by the 'Fonds zur Föderung der Wissenschaftlichen Forschung, Austria', during an 'Erwin-Schrödinger' fellowship, project J01098-GEO. G.R.R. acknowledges support from the National Science Foundation, grant EAR 9218980. The comments of two referees helped to improve the manuscript.
Funders:
Funding AgencyGrant Number
Fonds zur Föderung der Wissenschaftlichen Forschung AustriaJ01098-GEO
NSFEAR 9218980
Record Number:CaltechAUTHORS:20130801-092700993
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:20130801-092700993
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:39698
Collection:CaltechAUTHORS
Deposited By: Jason Perez
Deposited On:01 Aug 2013 20:54
Last Modified:07 Feb 2017 03:57

Repository Staff Only: item control page