Bubble Formation on St. Jude Medical Mechanical Heart Valves: An In-Vitro Study

Milo, Simcha and Gutfinger, Chaim and Chu, Gina Yu-chi and Gharib, Morteza (2003) Bubble Formation on St. Jude Medical Mechanical Heart Valves: An In-Vitro Study. Journal of Heart Valve Disease, 12 (3). pp. 406-410. ISSN 0966-8519. https://resolver.caltech.edu/CaltechAUTHORS:20130912-082111144

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20130912-082111144

Abstract

Background and aim of the study: Bubble formation in blood, which has been observed during valve closure in patients with mechanical heart valves (MHVs), raises concern because of cognitive changes and potential activation of blood elements associated with thromboembolic phenomena. Bubble formation in the vicinity of MHVs has been described previously; the present in-vitro study was undertaken to quantitate bubbles leaving the heart and entering the systemic circulation, and to gain a closer perspective of this phenomenon and its potential clinical implications. Methods: Experiments were performed in a left heart pulsed flow simulator with 29 mm mitral and 23 mm aortic St. Jude Medical MHVs; mitral and aortic bioprosthetic valves were used as controls. De-aerated water was pumped through the left heart pulsed flow simulator at a fixed rate of 70 beats/min and at different cardiac outputs. Bubble numbers and sizes were monitored photographically at the simulator exit. Results: Numbers of bubbles per frame generated in MHVs in the mitral position ranged from 8 to 14 at cardiac outputs of 3 to 6.5 l/min; this corresponded to gas volumetric flow rates of 330 to 830 mm^3/min. The number of bubbles per frame for the aortic MHV was 3 to 7, reflecting the less severe flow conditions and milder valve closure impact. The diameter of bubbles generated by the mitral valve was almost uniform (0.45 mm), while bubble diameters in the aortic valve ranged from 0.36 to 0.69 mm. Conclusion: Bubble formation was found to be an inherent flaw of the present generation of MHVs, and this problem should be addressed in future valve designs.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://www.icr-heart.com/?cid=1133PublisherArticle
Additional Information:© 2003 ICR Publishers.
Group:GALCIT
Issue or Number:3
Record Number:CaltechAUTHORS:20130912-082111144
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20130912-082111144
Official Citation:The Journal of Heart Valve Disease 2003;12:406-410
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:41271
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:17 Sep 2013 20:12
Last Modified:03 Oct 2019 05:47

Repository Staff Only: item control page