The Scanning DMA Transfer Function

Collins, Don R. and Cocker, David R., III and Flagan, Richard C. and Seinfeld, John H. (2004) The Scanning DMA Transfer Function. Aerosol Science and Technology, 38 (8). pp. 833-850. ISSN 0278-6826. doi:10.1080/027868290503082. https://resolver.caltech.edu/CaltechAUTHORS:20150818-102011829

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20150818-102011829

Abstract

The scanning differential mobility analyzer (DMA) has been widely employed for measurement of rapidly evolving aerosol size distributions. Interpretation of data from scanning DMAs is greatly facilitated when an exponential voltage ramp is prescribed, since the shape of the instrumental transfer function remains constant throughout a scan. However, that transfer function may differ significantly from that expected for fixed voltage operation. Because no simple analytical description of the scanning DMA transfer function exists, it has been evaluated numerically by simulating particle trajectories within a TSI 3081 cylindrical DMA. These computations yield transfer functions for the DMA up scan that are roughly triangular but with widths significantly greater than those for fixed voltage operation, and transfer functions for the down scan that are highly asymmetric. The impact of these distortions is most obvious when the size distribution of the measured aerosol is narrow, but errors in recovered size and concentration can be significant even when the aerosol size distribution is much broader than the transfer function. The magnitude of these errors is dependent upon the ratio of the mean gas residence time to the exponential voltage time constant, the sheath-to-aerosol-flow ratio, and the technique used to determine the instrument plumbing time. Experimental results for scans across broad and narrow size distributions compare favorably with predictions based on the simulated transfer functions. Simplified corrections are provided that can be used to adjust the concentration and mobility of size distributions recovered using a fixed voltage transfer function.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1080/027868290503082DOIArticle
http://www.tandfonline.com/doi/abs/10.1080/027868290503082PublisherArticle
ORCID:
AuthorORCID
Cocker, David R., III0000-0002-0586-0769
Flagan, Richard C.0000-0001-5690-770X
Seinfeld, John H.0000-0003-1344-4068
Additional Information:© 2004 American Association for Aerosol Research. Received 13 February 2004; accepted 24 June 2004. We are grateful for support received from the NSF Atmospheric Chemistry and Physical Meteorology Programs through grant ATM-0094342. The authors wish to thank Patrick Chuang and Jian Wang for their assistance during the data collection. We would also like to thank the reviewers of this article for their insightful and extremely helpful suggestions.
Funders:
Funding AgencyGrant Number
NSFATM-0094342
Issue or Number:8
DOI:10.1080/027868290503082
Record Number:CaltechAUTHORS:20150818-102011829
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20150818-102011829
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:59703
Collection:CaltechAUTHORS
Deposited By: Irina Meininger
Deposited On:20 Aug 2015 16:33
Last Modified:10 Nov 2021 22:24

Repository Staff Only: item control page