Christiansen, Walter H. (1960) Use of Fine Unheated Wires for Heat Transfer Measurements in the Shock Tube. Hypersonic Research Project Memorandum, 55. California Institute of Technology , Pasadena, CA. (Unpublished) https://resolver.caltech.edu/CaltechAUTHORS:20151104-151224999
![]() |
PDF
- Submitted Version
See Usage Policy. 8MB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20151104-151224999
Abstract
This report describes the application of fine cold wires for heat transfer measurements in the shock tube. The use of the calorimetric property of the wire results in a heat transfer instrument with an output of .25 mv/oC and a response lag of less than 1 µsec. The gage construction, calibration, and response characteristics are discussed. Some preliminary results are also presented.
Item Type: | Report or Paper (Technical Report) | ||||
---|---|---|---|---|---|
Additional Information: | Army Ordnance Contract No. DA-04-495-Ord-1960. | ||||
Group: | Hypersonic Research Project, GALCIT | ||||
Funders: |
| ||||
Series Name: | Hypersonic Research Project Memorandum | ||||
Issue or Number: | 55 | ||||
Record Number: | CaltechAUTHORS:20151104-151224999 | ||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20151104-151224999 | ||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | ||||
ID Code: | 61852 | ||||
Collection: | CaltechAUTHORS | ||||
Deposited By: | Kristin Buxton | ||||
Deposited On: | 05 Nov 2015 02:49 | ||||
Last Modified: | 03 Oct 2019 09:12 |