CaltechAUTHORS
  A Caltech Library Service

Isolation of circulating tumor cells by a magnesium-embedded filter

Liu, Yang and Xu, Tong and Xu, Yucheng and Kang, Dongyang and Xu, Lei and Park, Jungwook and Chang, Jay Han-Chieh and Zhang, Xiaoxiao and Goldkorn, Amir and Tai, Yu-Chong (2015) Isolation of circulating tumor cells by a magnesium-embedded filter. Journal of Micromechanics and Microengineering, 25 (10). Art. No. 104002. ISSN 0960-1317. http://resolver.caltech.edu/CaltechAUTHORS:20160108-121609556

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20160108-121609556

Abstract

Circulating tumor cells (CTCs) are rare cancer cells that are shed by tumors into the bloodstream and that can be valuable biomarkers for various types of cancers. However, CTCs captured on the filter could not be released easily using the existing CTC analysis platforms based on size. To address this limitation, we have developed a novel magnesium (Mg)-embedded cell filter for capture, release and isolation of CTCs. The CTC-filter consists of a thin Ebeam-deposited Mg layer embedded between two parylene-C (PA-C) layers with designed slots for filtration and CTC capture. Thin Mg film has proved highly biocompatible and can be etched in saline, PBS and Dulbecco's modified eagle medium (DMEM) etc, properties that are of great benefit to help dissociate the filter and thus release the cells. The finite element method (FEM) analysis was performed on the Mg etching process in DMEM for the structure design. After the filtration process, the filter was submerged in DMEM to facilitate Mg etching. The top PA-C filter pieces break apart from the bottom after Mg completely dissolves, enabling captured CTCs to detach. The released CTC can be easily aspirated into a micropipette for further analysis. Thus, the Mg-embedded cell filter provides a new and effective approach for CTCs isolation from the filter, making this a promising new strategy for cancer detection.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1088/0960-1317/25/10/104002DOIArticle
http://iopscience.iop.org/article/10.1088/0960-1317/25/10/104002PublisherArticle
ORCID:
AuthorORCID
Tai, Yu-Chong0000-0001-8529-106X
Additional Information:© 2015 IOP Publishing Ltd. Received 10 March 2015, revised 15 July 2015. Accepted for publication 20 July 2015. Published 21 September 2015. The authors gratefully acknowledge the help of all the members of the California Institute of Technology (Caltech) Micromachining Lab, and University of Southern California (USC) Keck School of Medicine Norris Comprehensive Cancer Center, as well as the experimental assistance of Mr Trevor Roper.
Subject Keywords:circulating tumor cell (CTC), CTC filter, magnesium (Mg), biodegradable
Record Number:CaltechAUTHORS:20160108-121609556
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:20160108-121609556
Official Citation:Yang Liu et al 2015 J. Micromech. Microeng. 25 104002
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.