CaltechAUTHORS
  A Caltech Library Service

Photoacoustic computed tomography correcting for heterogeneity and attenuation

Huang, Chao and Nie, Liming and Schoonover, Robert W. and Wang, Lihong V. and Anastasio, Mark A. (2012) Photoacoustic computed tomography correcting for heterogeneity and attenuation. Journal of Biomedical Optics, 17 (6). Art. No. 061211. ISSN 1083-3668. PMCID PMC3380947. https://resolver.caltech.edu/CaltechAUTHORS:20160812-143631376

[img] PDF - Published Version
See Usage Policy.

911Kb

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20160812-143631376

Abstract

We report an investigation of image reconstruction in photoacoustic tomography for objects that possess heterogeneous material and acoustic attenuation distributions. When the object contains materials, such as bone and soft-tissue, that are modeled using power law attenuation models with distinct exponents, we demonstrate that the effects of acoustic attenuation due to the most strongly attenuating material can be compensated for if the attenuation of the other less attenuating material(s) are neglected. Experiments with phantom objects are presented to validated our findings.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1117/1.JBO.17.6.061211DOIArticle
http://biomedicaloptics.spiedigitallibrary.org/article.aspx?articleid=1306195PublisherArticle
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3380947/PubMed CentralArticle
ORCID:
AuthorORCID
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2012 SPIE. Paper 11610SS received Oct. 18, 2011; revised manuscript received Jan. 20, 2012; accepted for publication Jan. 20, 2012; published online May 7, 2012. The authors acknowledge Brad Treeby and Ben Cox for helpful discussions regarding the k-Wave toolbox and Zijian Guo for useful discussions regarding the design of the experiment. Chao Huang, Robert W. Schoonover, and Mark A. Anastasio acknowledge support in part by NIH awards EB010049 and EB009715. Liming Nie and Lihong V. Wang acknowledge support by the NIH awards EB010049, CA134539, EB000712, CA136398, and EB008085. L.V.W. has a financial interest in Microphotoacoustics, Inc. and Endra, Inc., which, however, did not support this work.
Funders:
Funding AgencyGrant Number
NIHEB010049
NIHEB009715
NIHCA134539
NIHEB000712
NIHCA136398
NIHEB008085
Subject Keywords:attenuation; image reconstruction; photoacoustics; tomography
Issue or Number:6
PubMed Central ID:PMC3380947
Record Number:CaltechAUTHORS:20160812-143631376
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20160812-143631376
Official Citation:Huang C, Nie L, Schoonover RW, Wang LV, Anastasio MA; Photoacoustic computed tomography correcting for heterogeneity and attenuation. J. Biomed. Opt. 0001;17(6):061211-1-061211-5. doi:10.1117/1.JBO.17.6.061211
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:69607
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:12 Aug 2016 22:11
Last Modified:03 Oct 2019 10:23

Repository Staff Only: item control page