CaltechAUTHORS
  A Caltech Library Service

Adaptive and Robust Methods of Reconstruction (ARMOR) for Thermoacoustic Tomography

Xie, Yao and Guo, Bin and Liu, Jian and Ku, Geng and Wang, Lihong V. (2008) Adaptive and Robust Methods of Reconstruction (ARMOR) for Thermoacoustic Tomography. IEEE Transactions on Biomedical Engineering, 55 (12). pp. 2741-2752. ISSN 0018-9294. doi:10.1109/TBME.2008.919112. https://resolver.caltech.edu/CaltechAUTHORS:20160921-155919948

[img] PDF - Published Version
See Usage Policy.

1MB

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20160921-155919948

Abstract

In this paper, we present new adaptive and robust methods of reconstruction (ARMOR) for thermoacoustic tomography (TAT), and study their performances for breast cancer detection. TAT is an emerging medical imaging technique that combines the merits of high contrast due to electromagnetic or laser stimulation and high resolution offered by thermal acoustic imaging. The current image reconstruction methods used for TAT, such as the delay-and-sum (DAS) approach, are data-independent and suffer from low-resolution, high sidelobe levels, and poor interference rejection capabilities. The data-adaptive ARMOR can have much better resolution and much better interference rejection capabilities than their data-independent counterparts. By allowing certain uncertainties, ARMOR can be used to mitigate the amplitude and phase distortion problems encountered in TAT. The excellent performance of ARMOR is demonstrated using both simulated and experimentally measured data.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1109/TBME.2008.919112DOIArticle
http://ieeexplore.ieee.org/document/4457879/?arnumber=4457879PublisherArticle
ORCID:
AuthorORCID
Liu, Jian0000-0001-8552-1400
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2008 IEEE. Manuscript received May 8, 2007; revised October 22, 2007. First published February 25, 2008; current version published December 17, 2008. This work was supported in part by the National Institutes of Health (NIH) under Grant 1R41CA107903-1, in part by the U.S. Army Medical Command under Contract W81XWH-06-1-0389, and in part by the National Natural Science Foundation of China under Grant 60428101.
Funders:
Funding AgencyGrant Number
NIH1R41CA107903-1
U.S. Army Medical CommandW81XWH-06-1-0389
National Natural Science Foundation of China60428101
Subject Keywords:Array signal processing, biomedical acoustic imaging, robustness
Issue or Number:12
DOI:10.1109/TBME.2008.919112
Record Number:CaltechAUTHORS:20160921-155919948
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20160921-155919948
Official Citation:Y. Xie, B. Guo, J. Li, G. Ku and L. V. Wang, "Adaptive and Robust Methods of Reconstruction (ARMOR) for Thermoacoustic Tomography," in IEEE Transactions on Biomedical Engineering, vol. 55, no. 12, pp. 2741-2752, Dec. 2008. doi: 10.1109/TBME.2008.919112 Y. Xie*, B. Guo, J. Li, G. Ku and L. V. Wang, "Adaptive and Robust Methods of Reconstruction (ARMOR) for Thermoacoustic Tomography," in IEEE Transactions on Biomedical Engineering, vol. 55, no. 12, pp. 2741-2752, Dec. 2008. doi: 10.1109/TBME.2008.919112
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:70526
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:30 Sep 2016 19:30
Last Modified:11 Nov 2021 04:30

Repository Staff Only: item control page