CaltechAUTHORS
  A Caltech Library Service

Evaluation of the magneto-optical effect in biological tissue models using optical coherence tomography

Pereda-Cubián, David and Todorović, Miloš and Arce-Diego, José Luis and Wang, Lihong V. (2007) Evaluation of the magneto-optical effect in biological tissue models using optical coherence tomography. Journal of Biomedical Optics, 12 (6). Art. No. 060502. ISSN 1083-3668. doi:10.1117/1.2818103. https://resolver.caltech.edu/CaltechAUTHORS:20161005-080655639

[img] PDF - Published Version
See Usage Policy.

165kB

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20161005-080655639

Abstract

For the first time to our knowledge, an experimental evaluation of the Faraday effect–induced polarization rotation in a biological tissue phantom is reported. The rotation of the polarization plane produced in the optical beam propagating through an Intralipid solution was evaluated using polarization-sensitive optical coherence tomography (PS-OCT), and the experimental results closely matched the theoretical values. The angle of rotation is proportional to the traversed path length along the magnetic field and can potentially be used to estimate the actual penetration depth.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1117/1.2818103DOIArticle
http://biomedicaloptics.spiedigitallibrary.org/article.aspx?articleid=1351956PublisherArticle
ORCID:
AuthorORCID
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2007 SPIE. Paper 07162LR received May 5, 2007; revised manuscript received Aug. 9, 2007; accepted for publication Sep. 5, 2007; published online Dec. 11, 2007. This project has been sponsored in part by the Fulbright Commission through a Spanish Fulbright/MEC (Ministerio de Educación y Ciencia) scholarship, as well as by the National Institutes of Health Grant No. R01 CA092415 and the Spanish MEC project TCE2006-06548/TCM.
Funders:
Funding AgencyGrant Number
Fulbright FoundationUNSPECIFIED
NIHR01 CA092415
Ministerio de Educación y Ciencia (MEC)TCE2006-06548/TCM
Subject Keywords:tomography; polarization; magneto-optics; fiber optics
Issue or Number:6
DOI:10.1117/1.2818103
Record Number:CaltechAUTHORS:20161005-080655639
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20161005-080655639
Official Citation:Pereda-Cubián D, Todorović M, Arce-Diego J, Wang LV; Evaluation of the magneto-optical effect in biological tissue models using optical coherence tomography. J. Biomed. Opt. 0001;12(6):060502-060502-3
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:70856
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:05 Oct 2016 16:44
Last Modified:11 Nov 2021 04:36

Repository Staff Only: item control page