Pereda-Cubián, David and Todorović, Miloš and Arce-Diego, José Luis and Wang, Lihong V. (2007) Evaluation of the magneto-optical effect in biological tissue models using optical coherence tomography. Journal of Biomedical Optics, 12 (6). Art. No. 060502. ISSN 1083-3668. doi:10.1117/1.2818103. https://resolver.caltech.edu/CaltechAUTHORS:20161005-080655639
![]() |
PDF
- Published Version
See Usage Policy. 165kB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20161005-080655639
Abstract
For the first time to our knowledge, an experimental evaluation of the Faraday effect–induced polarization rotation in a biological tissue phantom is reported. The rotation of the polarization plane produced in the optical beam propagating through an Intralipid solution was evaluated using polarization-sensitive optical coherence tomography (PS-OCT), and the experimental results closely matched the theoretical values. The angle of rotation is proportional to the traversed path length along the magnetic field and can potentially be used to estimate the actual penetration depth.
Item Type: | Article | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| |||||||||
ORCID: |
| |||||||||
Additional Information: | © 2007 SPIE. Paper 07162LR received May 5, 2007; revised manuscript received Aug. 9, 2007; accepted for publication Sep. 5, 2007; published online Dec. 11, 2007. This project has been sponsored in part by the Fulbright Commission through a Spanish Fulbright/MEC (Ministerio de Educación y Ciencia) scholarship, as well as by the National Institutes of Health Grant No. R01 CA092415 and the Spanish MEC project TCE2006-06548/TCM. | |||||||||
Funders: |
| |||||||||
Subject Keywords: | tomography; polarization; magneto-optics; fiber optics | |||||||||
Issue or Number: | 6 | |||||||||
DOI: | 10.1117/1.2818103 | |||||||||
Record Number: | CaltechAUTHORS:20161005-080655639 | |||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20161005-080655639 | |||||||||
Official Citation: | Pereda-Cubián D, Todorović M, Arce-Diego J, Wang LV; Evaluation of the magneto-optical effect in biological tissue models using optical coherence tomography. J. Biomed. Opt. 0001;12(6):060502-060502-3 | |||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | |||||||||
ID Code: | 70856 | |||||||||
Collection: | CaltechAUTHORS | |||||||||
Deposited By: | Tony Diaz | |||||||||
Deposited On: | 05 Oct 2016 16:44 | |||||||||
Last Modified: | 11 Nov 2021 04:36 |
Repository Staff Only: item control page