CaltechAUTHORS
  A Caltech Library Service

Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels

Sivaramakrishnan, Mathangi and Maslov, Konstantin and Zhang, Hao F. and Stoica, George and Wang, Lihong V. (2007) Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels. Physics in Medicine and Biology, 52 (5). pp. 1349-1361. ISSN 0031-9155. doi:10.1088/0031-9155/52/5/010. https://resolver.caltech.edu/CaltechAUTHORS:20161005-085823162

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20161005-085823162

Abstract

We investigate the feasibility of obtaining accurate quantitative information, such as local blood oxygenation level (sO_2), with a spatial resolution of about 50 µm from spectral photoacoustic (PA) measurements. The optical wavelength dependence of the peak values of the PA signals is utilized to obtain the local blood oxygenation level. In our in vitro experimental models, the PA signal amplitude is found to be linearly proportional to the blood optical absorption coefficient when using ultrasonic transducers with central frequencies high enough such that the ultrasonic wavelengths are shorter than the light penetration depth into the blood vessels. For an optical wavelength in the 578–596 nm region, with a transducer central frequency that is above 25 MHz, the sensitivity and accuracy of sO_2 inversion is shown to be better than 4%. The effect of the transducer focal position on the accuracy of quantifying blood oxygenation is found to be negligible. In vivo oxygenation measurements of rat skin microvasculature yield results consistent with those from in vitro studies, although factors specific to in vivo measurements, such as the spectral dependence of tissue optical attenuation, dramatically affect the accuracy of sO_2 quantification in vivo.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1088/0031-9155/52/5/010DOIArticle
http://iopscience.iop.org/article/10.1088/0031-9155/52/5/010/metaPublisherArticle
ORCID:
AuthorORCID
Maslov, Konstantin0000-0003-3408-8840
Stoica, George0000-0001-8071-4828
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2007 IOP Publishing Ltd. Received 15 June 2006; In final form 3 January 2007; Published 8 February 2007.
Issue or Number:5
DOI:10.1088/0031-9155/52/5/010
Record Number:CaltechAUTHORS:20161005-085823162
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20161005-085823162
Official Citation:Mathangi Sivaramakrishnan et al 2007 Phys. Med. Biol. 52 1349
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:70867
Collection:CaltechAUTHORS
Deposited By: Tony Diaz
Deposited On:05 Oct 2016 16:16
Last Modified:11 Nov 2021 04:36

Repository Staff Only: item control page