CaltechAUTHORS
  A Caltech Library Service

Determination of Differential Mobility Analyzer Transfer Functions Using Identical Instruments in Series

Birmili, W. and Stratmann, F. and Wiedensohler, A. and Covert, D. and Russell, L. M. and Berg, O. (1997) Determination of Differential Mobility Analyzer Transfer Functions Using Identical Instruments in Series. Aerosol Science and Technology, 27 (2). pp. 215-223. ISSN 0278-6826. doi:10.1080/02786829708965468. https://resolver.caltech.edu/CaltechAUTHORS:20170408-154823553

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20170408-154823553

Abstract

The differential mobility analyzer (DMA) is an important tool for determining particle size distributions. The physical performance of a DMA is quantified by the concept of the transfer function. Therefore, knowledge of the transfer function is important to interpret the mobility distributions recorded by a DMA. During a calibration workshop in preparation for the Aerosol Characterization Experiment 1 (ACE1) field campaign, the transfer functions of five types of different mobility analyzers (Vienna-type DMA short, medium, and long, CIT radial, and TSI long; CIT = California Institute of Technology, Pasadena, CA; TST = TSI Inc., St. Paul, MN) were experimentally characterized by height, width, and area of their transfer functions. Different particles size ranges between 3 and 200 nm were investigated. The transfer function was determined by scanning a DMA across the mobility distribution produced by another, identical DMA. Subsequently, the data were processed by a deconvolution algorithm assuming a triangular shape for the transfer function. For all DMA types, the area of the transfer function decreased with particle size, especially for ultrafine particles (d_p < 20 nm). The gradient with which this area decreases with particle size, however, is different for each of the DMA types investigated. The calibration provides an improved description of the performance of each DMA, particularly in the ultrafine size range.


Item Type:Article
Related URLs:
URLURL TypeDescription
http://dx.doi.org/10.1080/02786829708965468DOIArticle
ORCID:
AuthorORCID
Russell, L. M.0000-0002-6108-2375
Additional Information:© 1997 American Association for Aerosol Research. Received 4 April 1996; accepted 16 December 1996. L. M. R. appreciates the support of the National Science Foundation (grant ATM-9307603) and the Office of Naval Research for participation in ACE1 activities.
Funders:
Funding AgencyGrant Number
NSFATM-9307603
Office of Naval Research (ONR)UNSPECIFIED
Issue or Number:2
DOI:10.1080/02786829708965468
Record Number:CaltechAUTHORS:20170408-154823553
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20170408-154823553
Official Citation: W. Birmili , F. Stratmann , A. Wiedensohler , D. Covert , L. M. Russell & O. Berg (1997) Determination of Differential Mobility Analyzer Transfer Functions Using Identical Instruments in Series, Aerosol Science and Technology, 27:2, 215-223, DOI: 10.1080/02786829708965468
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:76071
Collection:CaltechAUTHORS
Deposited By: 1Science Import
Deposited On:19 May 2017 23:09
Last Modified:15 Nov 2021 16:57

Repository Staff Only: item control page