CaltechAUTHORS
  A Caltech Library Service

Enhancement of the Spitzer Infrared Array Camera (IRAC) distortion correction for parallax measurements

Lowrance, Patrick J. and Carey, Sean J. and Ingalls, James G. and Surace, Jason A. and Capak, Peter and Stauffer, John and Beichman, Chas and Shupe, David and Kirkpatrick, J. Davy (2014) Enhancement of the Spitzer Infrared Array Camera (IRAC) distortion correction for parallax measurements. In: Space Telescopes and Instrumentation 2014: Optical, Infrared, and Millimeter Wave. Proceedings of SPIE. No.9143. Society of Photo-optical Instrumentation Engineers (SPIE) , Bellingham, WA, Art. No. 914358. ISBN 9780819496119. https://resolver.caltech.edu/CaltechAUTHORS:20180713-114823898

[img] PDF - Published Version
See Usage Policy.

1414Kb

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20180713-114823898

Abstract

The Spitzer Space Telescope Infrared Array (IRAC) offers a rare opportunity to measure distances and determine physical properties of the faintest and coldest brown dwarfs. The current distortion correction is a 3rd order polynomial represented by TAN-SIP parameters within the headers. The current correction, good to 100 mas, was derived from deep imaging, using marginally resolved galaxies in some cases, and has remained stable throughout both the cryogenic and warm mission. Using recent Spitzer calibration observations mapped to HST/ACS calibration observations of 47 Tuc with an absolute accuracy good to 1 mas, we are working towards a possible 5th order polynomial correction that theoretically could allow measurements to within 20 mas. Extensive testing, using observations of 47 Tuc, NGC 6791 and NGC 2264, are underway, after which the new parameters will be used to update all the 3.6 and 4.5um data taken within warm and cryogenic missions. We anticipate if achievable, this new accuracy could be combined with other ongoing enhancements (Ingalls et al, 9143-52) that will permit measurements of parallaxes out to about 50 pc, increasing the volume surveyed by a factor of 100, and enabling new capabilities such as luminosity measurements of the population of young brown dwarfs in the beta Pictoris moving group.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
https://doi.org/10.1117/12.2057195DOIArticle
ORCID:
AuthorORCID
Lowrance, Patrick J.0000-0001-8014-0270
Carey, Sean J.0000-0002-0221-6871
Ingalls, James G.0000-0003-4714-1364
Surace, Jason A.0000-0001-7291-0087
Capak, Peter0000-0003-3578-6843
Stauffer, John0000-0003-3595-7382
Beichman, Chas0000-0002-5627-5471
Shupe, David0000-0003-4401-0430
Kirkpatrick, J. Davy0000-0003-4269-260X
Additional Information:© 2014 Society of Photo-Optical Instrumentation Engineers (SPIE).
Group:Infrared Processing and Analysis Center (IPAC)
Subject Keywords:infrared, distortion, calibrations, parallax, brown dwarfs
Series Name:Proceedings of SPIE
Issue or Number:9143
Record Number:CaltechAUTHORS:20180713-114823898
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20180713-114823898
Official Citation:Patrick J. Lowrance, Sean J. Carey, James G. Ingalls, Jason A. Surace, Peter Capak, John Stauffer, Chas Beichman, David Shupe, J. Davy Kirkpatrick, "Enhancement of the Spitzer Infrared Array Camera (IRAC) distortion correction for parallax measurements", Proc. SPIE 9143, Space Telescopes and Instrumentation 2014: Optical, Infrared, and Millimeter Wave, 914358 (28 August 2014); doi: 10.1117/12.2057195; https://doi.org/10.1117/12.2057195
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:87829
Collection:CaltechAUTHORS
Deposited By: George Porter
Deposited On:16 Jul 2018 16:16
Last Modified:14 Nov 2019 23:46

Repository Staff Only: item control page