Nie, Liming and Huang, Chao and Guo, Zijian and Anastasio, Mark and Wang, Lihong V. (2012) Transcranial photoacoustic tomography of the monkey brain. In: Photons Plus Ultrasound: Imaging and Sensing 2012. Proceedings of SPIE. No.8223. Society of Photo-optical Instrumentation Engineers (SPIE) , Bellingham, WA, Art. No. 82230L. ISBN 9780819488664. https://resolver.caltech.edu/CaltechAUTHORS:20180918-140709994

[img] PDF - Published Version
See Usage Policy.

528Kb

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20180918-140709994

Abstract

A photoacoustic tomography (PAT) system using a virtual point ultrasonic transducer was developed for transcranial imaging of monkey brains. The virtual point transducer provided a 10 times greater field-of-view (FOV) than finiteaperture unfocused transducers, which enables large primate imaging. The cerebral cortex of a monkey brain was accurately mapped transcranially, through up to two skulls ranging from 4 to 8 mm in thickness. The mass density and speed of sound distributions of the skull were estimated from adjunct X-ray CT image data and utilized with a timereversal algorithm to mitigate artifacts in the reconstructed image due to acoustic aberration. The oxygenation saturation (sO_2) in blood phantoms through a monkey skull was also imaged and quantified, with results consistent with measurements by a gas analyzer. The oxygenation saturation (sO_2) in blood phantoms through a monkey skull was also imaged and quantified, with results consistent with measurements by a gas analyzer. Our experimental results demonstrate that PAT can overcome the optical and ultrasound attenuation of a relatively thick skull, and the imaging aberration caused by skull can be corrected to a great extent.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
https://doi.org/10.1117/12.907060DOIArticle
ORCID:
AuthorORCID
Anastasio, Mark0000-0002-3192-4172
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). This research was supported by the National Institutes of Health (grants R01 EB010049, R01 CA134539, R01 EB000712, U54 CA136398, and R01 EB008085).
Funders:
Funding AgencyGrant Number
NIHR01 EB010049
NIHR01 CA134539
NIHR01 EB000712
NIHU54 CA136398
NIHR01 EB008085
Subject Keywords:Transcranial photoacoustic tomography, time-reversal image reconstruction
Series Name:Proceedings of SPIE
Issue or Number:8223
Record Number:CaltechAUTHORS:20180918-140709994
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20180918-140709994
Official Citation:Liming Nie, Liming Nie, Chao Huang, Chao Huang, Zijian Guo, Zijian Guo, Mark Anastasio, Mark Anastasio, Lihong V. Wang, Lihong V. Wang, } "Transcranial photoacoustic tomography of the monkey brain", Proc. SPIE 8223, Photons Plus Ultrasound: Imaging and Sensing 2012, 82230L (23 February 2012); doi: 10.1117/12.907060; https://doi.org/10.1117/12.907060
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:89730
Collection:CaltechAUTHORS
Deposited By: George Porter
Deposited On:19 Sep 2018 21:29
Last Modified:03 Oct 2019 20:18

Repository Staff Only: item control page