CaltechAUTHORS
  A Caltech Library Service

Volumetric photoacoustic endoscopy of internal organs: a phantom and in situ study

Yang, Joon-Mo and Maslov, Konstantin and Chen, Ruimin and Yang, Hao-Chung and Zhou, Qifa and Shung, K. Kirk and Wang, Lihong V. (2010) Volumetric photoacoustic endoscopy of internal organs: a phantom and in situ study. In: Photons Plus Ultrasound: Imaging and Sensing 2010. Proceedings of SPIE. No.7564. Society of Photo-optical Instrumentation Engineers (SPIE) , Bellingham, WA, Art. No. 75640D. ISBN 9780819479600. https://resolver.caltech.edu/CaltechAUTHORS:20180919-160038854

[img] PDF - Published Version
See Usage Policy.

3330Kb

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20180919-160038854

Abstract

In this study, we further developed our photoacoustic endoscopic system to produce three-dimensional images of internal organs by performing pullback C-scans. Employing the side-scanning photoacoustic endoscopic probe discussed in the Optical Society of America's journal Optics Letters, we could acquire successive B-scan images by pulling back the probe with a motorized linear stage. We demonstrate the endoscopic system's volumetric imaging ability through imaging of a metal wire phantom and an in situ rat rectum.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
https://doi.org/10.1117/12.842503DOIArticle
ORCID:
AuthorORCID
Maslov, Konstantin0000-0003-3408-8840
Chen, Ruimin0000-0002-5338-359X
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2010 Society of Photo-Optical Instrumentation Engineers (SPIE). This research was supported by the National Institutes of Health grants R01 NS46214 (BRP), R01 EB000712, R01 EB008085, and U54 CA136398 (Network for Translational Research). L.W. has a financial interest in Endra, Inc., which, however, did not support this work. J.-M. Y. was supported in part by a Korea Research Foundation (KRF) grant funded by the Korean Government (KRF-2007-357-C00039).The authors are grateful to Namiki Precision, Inc. for supporting the micromotors and Hitachi Cable Manchester for supporting the micro-coaxial cable.
Funders:
Funding AgencyGrant Number
NIHR01 NS46214
NIHR01 EB000712
NIHR01 EB008085
NIHU54 CA136398
National Research Foundation of KoreaKRF-2007-357-C00039
Subject Keywords:Photoacoustic endoscopy, volumetric imaging, tomography, internal organs, rectum, in situ imaging, optical biopsy
Series Name:Proceedings of SPIE
Issue or Number:7564
Record Number:CaltechAUTHORS:20180919-160038854
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20180919-160038854
Official Citation:Joon-Mo Yang, Joon-Mo Yang, Konstantin Maslov, Konstantin Maslov, Ruimin Chen, Ruimin Chen, Hao-Chung Yang, Hao-Chung Yang, Qifa Zhou, Qifa Zhou, K. Kirk Shung, K. Kirk Shung, Lihong V. Wang, Lihong V. Wang, } "Volumetric photoacoustic endoscopy of internal organs: a phantom and in situ study", Proc. SPIE 7564, Photons Plus Ultrasound: Imaging and Sensing 2010, 75640D (23 February 2010); doi: 10.1117/12.842503; https://doi.org/10.1117/12.842503