Jiao, Shuliang and Hsieh, Tseng-Ming and Ai, Jun and Todorovicc, Milos and Stoica, George and Wang, Lihong V. (2004) Fiber-based polarization-sensitive Mueller-matrix optical coherence tomography with continuous source polarization modulation. In: Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine VIII. Proceedings of SPIE. No.5316. Society of Photo-optical Instrumentation Engineers (SPIE) , Bellingham, WA, pp. 350-354. ISBN 9780819452245. https://resolver.caltech.edu/CaltechAUTHORS:20180927-114226242
![]() |
PDF
- Published Version
See Usage Policy. 259kB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20180927-114226242
Abstract
A novel fiber-based Mueller-matrix optical coherence tomography system is demonstrated for acquiring polarization images of biological tissues in vivo. The system features a single broadband source, a rapid scanning optical delay line, and an electro-optical polarization modulator that modulates the polarization states of the source light continuously. A frame of a 200 by 1515 pixel 2D image can be acquired in half a second. The Jones matrix of a sample is calculated from two frequency components--the A-scan carrier frequency component and the beat frequency component between the modulation frequency and the carrier frequency. For samples having negligible diattenuation, the Jones matrix can be calculated from a single measurement of either the horizontal or the vertical interference signal. The system was first validated by imaging standard polarization elements and then applied to imaging biological samples.
Item Type: | Book Section | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| ||||||||||
ORCID: |
| ||||||||||
Additional Information: | © 2004 Society of Photo-Optical Instrumentation Engineers (SPIE). This project was sponsored in part by National Institutes of Health grants R21 EB00319-02 and R01 EB000712, by National Science Foundation grant BES-9734491, and by Texas Higher Education Coordinating Board grant 000512-0063-2001. | ||||||||||
Funders: |
| ||||||||||
Subject Keywords: | optical coherence tomography, Mueller-matrix, Jones Matrix polarization | ||||||||||
Series Name: | Proceedings of SPIE | ||||||||||
Issue or Number: | 5316 | ||||||||||
DOI: | 10.1117/12.531022 | ||||||||||
Record Number: | CaltechAUTHORS:20180927-114226242 | ||||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20180927-114226242 | ||||||||||
Official Citation: | Shuliang Jiao, Shuliang Jiao, Tseng-Ming Hsieh, Tseng-Ming Hsieh, Jun Ai, Jun Ai, Milos Todorovic, Milos Todorovic, George Stoica, George Stoica, Lihong V. Wang, Lihong V. Wang, } "Fiber-based polarization-sensitive Mueller-matrix optical coherence tomography with continuous source polarization modulation", Proc. SPIE 5316, Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine VIII, (1 July 2004); doi: 10.1117/12.531022; https://doi.org/10.1117/12.531022 | ||||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | ||||||||||
ID Code: | 90023 | ||||||||||
Collection: | CaltechAUTHORS | ||||||||||
Deposited By: | George Porter | ||||||||||
Deposited On: | 31 Oct 2018 14:05 | ||||||||||
Last Modified: | 16 Nov 2021 00:40 |
Repository Staff Only: item control page