Jiao, Shuliang and Hsieh, Tseng-Ming and Ai, Jun and Todorovicc, Milos and Stoica, George and Wang, Lihong V. (2004) Fiber-based polarization-sensitive Mueller-matrix optical coherence tomography with continuous source polarization modulation. In: Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine VIII. Proceedings of SPIE. No.5316. Society of Photo-optical Instrumentation Engineers (SPIE) , Bellingham, WA, pp. 350-354. ISBN 9780819452245. http://resolver.caltech.edu/CaltechAUTHORS:20180927-114226242

[img] PDF - Published Version
See Usage Policy.

253Kb

Use this Persistent URL to link to this item: http://resolver.caltech.edu/CaltechAUTHORS:20180927-114226242

Abstract

A novel fiber-based Mueller-matrix optical coherence tomography system is demonstrated for acquiring polarization images of biological tissues in vivo. The system features a single broadband source, a rapid scanning optical delay line, and an electro-optical polarization modulator that modulates the polarization states of the source light continuously. A frame of a 200 by 1515 pixel 2D image can be acquired in half a second. The Jones matrix of a sample is calculated from two frequency components--the A-scan carrier frequency component and the beat frequency component between the modulation frequency and the carrier frequency. For samples having negligible diattenuation, the Jones matrix can be calculated from a single measurement of either the horizontal or the vertical interference signal. The system was first validated by imaging standard polarization elements and then applied to imaging biological samples.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
https://doi.org/10.1117/12.531022DOIArticle
ORCID:
AuthorORCID
Stoica, George0000-0001-8071-4828
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2004 Society of Photo-Optical Instrumentation Engineers (SPIE). This project was sponsored in part by National Institutes of Health grants R21 EB00319-02 and R01 EB000712, by National Science Foundation grant BES-9734491, and by Texas Higher Education Coordinating Board grant 000512-0063-2001.
Funders:
Funding AgencyGrant Number
NIHR21 EB00319-02
NIHR01 EB000712
NSFBES-9734491
Texas Higher Education Coordinating Board000512-0063-2001
Subject Keywords:optical coherence tomography, Mueller-matrix, Jones Matrix polarization
Record Number:CaltechAUTHORS:20180927-114226242
Persistent URL:http://resolver.caltech.edu/CaltechAUTHORS:20180927-114226242
Official Citation:Shuliang Jiao, Shuliang Jiao, Tseng-Ming Hsieh, Tseng-Ming Hsieh, Jun Ai, Jun Ai, Milos Todorovic, Milos Todorovic, George Stoica, George Stoica, Lihong V. Wang, Lihong V. Wang, } "Fiber-based polarization-sensitive Mueller-matrix optical coherence tomography with continuous source polarization modulation", Proc. SPIE 5316, Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine VIII, (1 July 2004); doi: 10.1117/12.531022; https://doi.org/10.1117/12.531022
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:90023
Collection:CaltechAUTHORS
Deposited By: George Porter
Deposited On:31 Oct 2018 14:05
Last Modified:31 Oct 2018 14:05

Repository Staff Only: item control page