Atanov, N. and Echenard, B. and Hitlin, D. G. and Miyashita, T. and Porter, F. and Zhu, R. Y. (2017) Quality Assurance on a custom SiPMs array for the Mu2e experiment. In: 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE , Piscataway, NJ, pp. 1-4. ISBN 978-1-5386-2282-7. https://resolver.caltech.edu/CaltechAUTHORS:20181126-155635040
Full text is not posted in this repository. Consult Related URLs below.
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20181126-155635040
Abstract
The Mu2e experiment at Fermilab will search for the coherent μ → e conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2ecalorimeter has been procured. A detailed quality assurance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.
Item Type: | Book Section | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| ||||||||||||||||
ORCID: |
| ||||||||||||||||
Additional Information: | © 2017 IEEE. This work was supported by the US Department of Energy; the Italian Istituto Nazionale di Fisica Nucleare; the US National Science Foundation; the Ministry of Education and Science of the Russian Federation; the Thousand Talents Plan of China; the Helmholtz Association of Germany; and the EU Horizon 2020 Research and Innovation Program under the Marie Sklodowska-Curie Grant Agreement No.690385. | ||||||||||||||||
Group: | CMS@Caltech | ||||||||||||||||
Funders: |
| ||||||||||||||||
Subject Keywords: | High energy physics instrumentation, Radiation effects, Silicon radiation detectors, Nuclear physics | ||||||||||||||||
DOI: | 10.1109/NSSMIC.2017.8533119 | ||||||||||||||||
Record Number: | CaltechAUTHORS:20181126-155635040 | ||||||||||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20181126-155635040 | ||||||||||||||||
Official Citation: | N. Atanov et al., "Quality Assurance on a custom SiPMs array for the Mu2e experiment," 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Atlanta, GA, USA, 2017, pp. 1-4. doi: 10.1109/NSSMIC.2017.8533119 | ||||||||||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | ||||||||||||||||
ID Code: | 91198 | ||||||||||||||||
Collection: | CaltechAUTHORS | ||||||||||||||||
Deposited By: | Tony Diaz | ||||||||||||||||
Deposited On: | 27 Nov 2018 17:55 | ||||||||||||||||
Last Modified: | 16 Nov 2021 03:39 |
Repository Staff Only: item control page