CaltechAUTHORS
  A Caltech Library Service

Slow light filters with MHz frequency resolution for enhancing the contrast in ultrasound-modulated optical tomography

Zhang, H. and Sabooni, M. and Rippe, L. and Kröll, S. and Kim, C. and Wang, L. V. and Hemmer, P. R. (2011) Slow light filters with MHz frequency resolution for enhancing the contrast in ultrasound-modulated optical tomography. In: 2011 Conference on Lasers and Electro-Optics Europe and 12th European Quantum Electronics Conference. IEEE , Piscataway, NJ, Art. No. CLEB2_3. ISBN 9781457705335. https://resolver.caltech.edu/CaltechAUTHORS:20190304-143521968

Full text is not posted in this repository. Consult Related URLs below.

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20190304-143521968

Abstract

The principal idea of UOT is to use the acousto-optic effect, where the ultrasound shifts the frequency of the light. The resolution of UOT (~ mm) is determined by the ultrasonic wave focus and duration, and the UOT contrast is determined by the optical properties of the tissue.


Item Type:Book Section
Related URLs:
URLURL TypeDescription
https://doi.org/10.1109/cleoe.2011.5943289DOIArticle
ORCID:
AuthorORCID
Wang, L. V.0000-0001-9783-4383
Additional Information:© 2011 IEEE.
Record Number:CaltechAUTHORS:20190304-143521968
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20190304-143521968
Official Citation:H. Zhang et al., "Slow light filters with MHz frequency resolution for enhancing the contrast in ultrasound-modulated optical tomography," 2011 Conference on Lasers and Electro-Optics Europe and 12th European Quantum Electronics Conference (CLEO EUROPE/EQEC), Munich, 2011, pp. 1-1. doi: 10.1109/CLEOE.2011.5943289
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:93451
Collection:CaltechAUTHORS
Deposited By: George Porter
Deposited On:04 Mar 2019 22:57
Last Modified:03 Oct 2019 20:54

Repository Staff Only: item control page