Xu, Yuan and Wang, Lihong V. (2002) Limited view thermoacoustic tomography. In: Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society. Vol.2. IEEE , Piscataway, NJ, pp. 937-938. ISBN 0780376129. https://resolver.caltech.edu/CaltechAUTHORS:20190304-143523105
![]() |
PDF
- Published Version
See Usage Policy. 183kB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20190304-143523105
Abstract
Truncated conjugate gradient method was applied to study the limited view problem in thermoacoustic tomography, and the results were compared with those of modified backprojection method, which is the backprojection of the first order time derivative of acoustic signals. Our numerical simulations showed that there is complete data for a stable and perfect reconstruction in a 2-D π-view problem, where the least angle acquired by the detection curve is π when viewed from the imaged region of interest. On the contrary, in a problem where the view is less than π, data is incomplete, and artifacts and quantitative errors were obvious in the reconstructed images. It was pointed out that the result after one iteration in truncated conjugate gradient method is equivalent to that of modified backprojection, which can restore the high frequency information of imaged objects. The low frequency information can be recovered significantly in the next ten iterations of truncated conjugate gradient method.
Item Type: | Book Section | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| ||||||||||||
ORCID: |
| ||||||||||||
Additional Information: | © 2002 IEEE. This project was sponsored in part by the U.S. Army Medical Research and Materiel Command Grant No. DAMD17-00-1-0455, the National Institutes of Health Grants No. R01 CA71980 and No. R21 CA83760, the National Science Foundation Grant No. BES-9734491, and Texas Higher Education Coordinating Board Grant No. ARP 000512-0123-1999. | ||||||||||||
Funders: |
| ||||||||||||
Subject Keywords: | Thermoacoustic tomography, limited view, truncated conjugate gradient | ||||||||||||
DOI: | 10.1109/iembs.2002.1106214 | ||||||||||||
Record Number: | CaltechAUTHORS:20190304-143523105 | ||||||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20190304-143523105 | ||||||||||||
Official Citation: | Yuan Xu and L. V. Wang, "Limited view thermoacoustic tomography," Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology, Houston, TX, USA, 2002, pp. 937-938 vol.2. doi: 10.1109/IEMBS.2002.1106214 | ||||||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | ||||||||||||
ID Code: | 93464 | ||||||||||||
Collection: | CaltechAUTHORS | ||||||||||||
Deposited By: | George Porter | ||||||||||||
Deposited On: | 05 Mar 2019 18:09 | ||||||||||||
Last Modified: | 16 Nov 2021 16:57 |
Repository Staff Only: item control page