CaltechAUTHORS
  A Caltech Library Service

Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system

Kim, Chulhong and Erpelding, Todd N. and Jankovic, Ladislav and Pashley, Michael D. and Wang, Lihong V. (2010) Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system. Biomedical Optics Express, 1 (1). pp. 278-284. ISSN 2156-7085. PMCID PMC3005157. https://resolver.caltech.edu/CaltechAUTHORS:20190304-153747357

[img] PDF - Published Version
See Usage Policy.

972Kb

Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20190304-153747357

Abstract

Using a hand-held photoacoustic probe integrated with a clinical ultrasound array system, we successfully imaged objects deeply positioned in biological tissues. The optical contrasts were enhanced by methylene blue with a concentration of ~30 mM. The penetration depth reached ~5.2 cm in chicken breast tissue by using 650-nm wavelength, which is ~4.7 times the 1/e optical penetration depth. This imaging depth was achieved using a laser fluence on the tissue surface of only 3 mJ/cm2, which is 1/7 of the American National Standards Institute (ANSI) safety limit (20 mJ/cm2). The noise equivalent sensitivity at this depth was ~11 mM. Further, after intradermal injection of methylene blue in a rat, a sentinel lymph node was easily detected in vivo, beneath a 2-cm thick layer of chicken breast. Also, blood located 3.5 cm deep in the rat was clearly imaged with intrinsic contrast. We have photoacoustically guided insertion of a needle into a rat sentinel lymph node with accumulated methylene blue. These results highlight the clinical potential of photoacoustic image-guided identification and needle biopsy of sentinel lymph nodes for axillary staging in breast cancer patients.


Item Type:Article
Related URLs:
URLURL TypeDescription
https://doi.org/10.1364/boe.1.000278DOIArticle
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3005157/PubMed CentralArticle
ORCID:
AuthorORCID
Wang, Lihong V.0000-0001-9783-4383
Additional Information:© 2010 Optical Society of America. Received 15 Jun 2010; revised 20 Jul 2010; accepted 20 Jul 2010; published 26 Jul 2010. This work was supported in part by grants from the National Institutes of Health (Network for Translational Research U54 CA136398, R01 EB008085, and R01 EB000712). L.V.W. has a financial interest in Microphotoacoustics, Inc. and in Endra, Inc., which, however, did not support this work.
Funders:
Funding AgencyGrant Number
NIHU54 CA136398
NIHR01 EB008085
NIHR01 EB000712
Issue or Number:1
Classification Code:OCIS codes: (110.0110) Imaging systems; (170.0170) Medical optics and biotechnology; (170.5120) Photoacoustic imaging
PubMed Central ID:PMC3005157
Record Number:CaltechAUTHORS:20190304-153747357
Persistent URL:https://resolver.caltech.edu/CaltechAUTHORS:20190304-153747357
Official Citation:Chulhong Kim, Todd N. Erpelding, Ladislav Jankovic, Michael D. Pashley, and Lihong V. Wang, "Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system," Biomed. Opt. Express 1, 278-284 (2010)
Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:93508
Collection:CaltechAUTHORS
Deposited By: George Porter
Deposited On:04 Mar 2019 23:49
Last Modified:03 Oct 2019 20:55

Repository Staff Only: item control page