Adams, Mark L. and Quake, Stephen and Scherer, Axel (2002) On-chip absorption and fluorescence spectroscopy with polydimethylsiloxane (PDMS) microfluidic flow channels. In: 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings. IEEE , Piscataway, NJ, pp. 369-373. ISBN 0780374800. https://resolver.caltech.edu/CaltechAUTHORS:20190306-122403540
![]() |
PDF
- Published Version
See Usage Policy. 656kB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20190306-122403540
Abstract
We describe a system, which integrates PDMS microfluidic flow channels, a CMOS active pixel sensor (APS) imager, and commercial light sources for performing visible absorption and fluorescence spectroscopy. PDMS elastomer allows for spectroscopic measurements to be performed in the visible (350 to 750 nm) wavelength range. Along with a sensitive silicon photodetector such as an APS imager, measurements can be made on low concentrations of solutions by placing the microfluidic flow channels directly on the imager. Emission sources for absorption measurements are typically commercial LEDs with peak emission wavelengths that match the peak absorption wavelengths of the material under test. For calibration purposes, known dyes are tested and compared with the results obtained from the imager. Fluorescence measurements are performed in much the same way, but a band-blocking filter is placed between the microfluidic channels and the imager to greatly attenuate the pump wavelength. Typical emission sources for fluorescence are commercial Ar ion lasers and semiconductor lasers. We feel that the system has great advantages due to its miniaturized size and small fluid volumes required. Further system miniaturization is also possible due to the integration of emission sources and the expandability of CMOS imagers to integrate on board image processing.
Item Type: | Book Section | ||||||
---|---|---|---|---|---|---|---|
Related URLs: |
| ||||||
Additional Information: | © 2002 IEEE. We would like to thank the Department of Defense Advanced Research Projects Agency (DARPA) and the National Science Foundation (NSF) for their support of this research. We would also like to thank NASA's Jet Propulsion Laboratory and the Advanced Imaging group for providing the APS CMOS imager. | ||||||
Funders: |
| ||||||
Subject Keywords: | Micro-fluidics, Spectrometers, Hyper-spectral imaging | ||||||
DOI: | 10.1109/mmb.2002.1002348 | ||||||
Record Number: | CaltechAUTHORS:20190306-122403540 | ||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20190306-122403540 | ||||||
Official Citation: | M. L. Adams, S. Quake and A. Scherer, "On-chip absorption and fluorescence spectroscopy with polydimethylsiloxane (PDMS) microfluidic flow channels," 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578), Madison, WI, USA, 2002, pp. 369-373. doi: 10.1109/MMB.2002.1002348 | ||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | ||||||
ID Code: | 93590 | ||||||
Collection: | CaltechAUTHORS | ||||||
Deposited By: | George Porter | ||||||
Deposited On: | 07 Mar 2019 16:02 | ||||||
Last Modified: | 16 Nov 2021 16:59 |