Huang, Jin-Biao and Ho, Chih-Ming and Tung, Steve and Liu, Chang and Tai, Yu-Chong (1995) Micro thermal shear stress sensor with and without cavity underneath. In: Proceedings of 1995 IEEE Instrumentation and Measurement Technology Conference - IMTC '95. IEEE , Piscataway, NJ, pp. 171-174. ISBN 0780326156. https://resolver.caltech.edu/CaltechAUTHORS:20190429-151825052
![]() |
PDF
- Published Version
See Usage Policy. 469kB |
Use this Persistent URL to link to this item: https://resolver.caltech.edu/CaltechAUTHORS:20190429-151825052
Abstract
Micro hot-film shear-stress sensors have been designed and fabricated by surface micromachining technology compatible with IC technology. A poly-silicon strip, 2 µm x 80 µm, is deposited on the top of a thin silicon nitride film and functions as the sensor element. By using sacrificial-layer technique, a cavity (vacuum chamber), 200 x 200 x 2 µm^3, is placed between the silicon nitride film and silicon substrate. This cavity significantly decreases the heat loss to the substrate. For comparison purposes, a sensor structure without a cavity has also been designed and fabricated on the same chip. Theoretical analyses for the two vertical structures with and without a cavity show that the former has a lower frequency response and higher sensitivity than the latter. When the sensor is operated in constant temperature mode, the cut-off frequencies can reach 130 k-Hz and 9 k-Hz respectively for the sensors without and with cavities.
Item Type: | Book Section | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Related URLs: |
| |||||||||
ORCID: |
| |||||||||
Additional Information: | © 1995 IEEE. This work is supported by AFOSR URI project (University Research Initiative). | |||||||||
Funders: |
| |||||||||
DOI: | 10.1109/imtc.1995.515123 | |||||||||
Record Number: | CaltechAUTHORS:20190429-151825052 | |||||||||
Persistent URL: | https://resolver.caltech.edu/CaltechAUTHORS:20190429-151825052 | |||||||||
Official Citation: | Jin-Biao Huang, Chih-Ming Ho, Steve Tung, Chang Liu and Yu-Chong Tai, "Micro thermal shear stress sensor with and without cavity underneath," Proceedings of 1995 IEEE Instrumentation and Measurement Technology Conference - IMTC '95, Waltham, MA, USA, 1995, pp. 171-174. doi: 10.1109/IMTC.1995.515123 | |||||||||
Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. | |||||||||
ID Code: | 95092 | |||||||||
Collection: | CaltechAUTHORS | |||||||||
Deposited By: | George Porter | |||||||||
Deposited On: | 30 Apr 2019 14:13 | |||||||||
Last Modified: | 16 Nov 2021 17:10 |
Repository Staff Only: item control page