Enhancement of photoacoustic tomography by ultrasonic computed tomography based on optical excitation of elements of a full-ring transducer array
Abstract
Photoacoustic computed tomography (PACT) is a hybrid technique that combines optical excitation and ultrasonic detection to provide high-resolution images in deep tissues. In the image reconstruction, a constant speed of sound (SOS) is normally assumed. This assumption, however, is often not strictly satisfied in deep tissue imaging, due to acoustic heterogeneities within the object and between the object and the coupling medium. If these heterogeneities are not accounted for, they will cause distortions and artifacts in the reconstructed images. In this Letter, we incorporated ultrasonic computed tomography (USCT), which measures the SOS distribution within the object, into our full-ring array PACT system. Without the need for ultrasonic transmitting electronics, USCT was performed using the same laser beam as for PACT measurement. By scanning the laser beam on the array surface, we can sequentially fire different elements. As a first demonstration of the system, we studied the effect of acoustic heterogeneities on photoacoustic vascular imaging. We verified that constant SOS is a reasonable approximation when the SOS variation is small. When the variation is large, distortion will be observed in the periphery of the object, especially in the tangential direction.
Additional Information
© 2013 Optical Society of America. Received July 11, 2013; accepted July 22, 2013; posted July 25, 2013 (Doc. ID 193722); published August 14, 2013. The authors appreciate Prof. James Ballard's close reading of the manuscript. This work was sponsored in part by National Institutes of Health grants DP1 EB016986 (NIH Director's Pioneer Award), R01 EB016963, R01 EB008085, R01 CA134539, U54 CA136398, R01 CA157277, and R01 CA159959. L.W. has a financial interest in Microphotoacoustics, Inc. and Endra, Inc., which, however, did not support this work. K.M. has a financial interest in Microphotoacoustics, Inc., which, however, did not support this work.Attached Files
Published - ol-38-16-3140.pdf
Files
Name | Size | Download all |
---|---|---|
md5:4df741c8a1257b515240f9b1f19ea346
|
930.6 kB | Preview Download |
Additional details
- PMCID
- PMC3884569
- Eprint ID
- 69239
- Resolver ID
- CaltechAUTHORS:20160727-093707118
- NIH
- DP1 EB016986
- NIH
- R01 EB016963
- NIH
- R01 EB016963
- NIH
- R01 EB008085
- NIH
- R01 CA134539
- NIH
- U54 CA136398
- NIH
- R01 CA157277
- NIH
- R01 CA159959
- Created
-
2016-07-27Created from EPrint's datestamp field
- Updated
-
2021-11-11Created from EPrint's last_modified field