Published February 1, 1954 | Version public
Journal Article Open

Link Coupling for Nuclear Magnetic Resonance

Abstract

In an attempt to use proton magnetic resonance for regulation of magnetic fields of 10 kilogauss or more, it has been found that the conventional probe sample holder used by other investigators (1) gave inadequate, if any, resonance lines above 40 mc/sec. In such arrangements, the oscillator tank coil is at the end of a coaxial probe. The weaker lines at higher frequencies are attributed to the fact that the distributed inductance of the coaxial line becomes important as frequency is increased. To overcome this difficulty, we have employed a link-type coupling arrangement.

Additional Information

Copyright © 1954 American Institute of Physics. (Received September 14, 1953)

Files

RICrsi54.pdf

Files (104.0 kB)

Name Size Download all
md5:7fc01e4a51cf87f0d27fdbe61b95127e
104.0 kB Preview Download

Additional details

Identifiers

Eprint ID
10821
Resolver ID
CaltechAUTHORS:RICrsi54

Dates

Created
2008-06-12
Created from EPrint's datestamp field
Updated
2021-11-08
Created from EPrint's last_modified field