Published March 11, 2003 | Version Published
Book Section - Chapter Open

W/SiC X-ray multilayers optimized for use above 100 keV

Abstract

We have developed a new depth-graded multilayer system comprising W and SiC layers, suitable for use as hard X-ray reflective coatings operating in the energy range 100 - 200 keV. Grazing incidence X-ray reflectance at E=8 keV was used to characterize the interface widths, as well as the temporal and thermal stability in both periodic and depth-graded W/SiC structures, while synchrotron radiation was used to measure the hard X-ray reflectance of a depth-graded multilayer designed specifically for use in the range E~150 - 170 keV. We have modeled the hard X-ray reflectance using newly-derived optical constants, which we determined from reflectance-vs-incidence angle measurements also made using synchrotron radiation, in the range E=120 - 180 keV. We describe our experimental investigation in detail, compare the new W/SiC multilayers with both W/Si and W/B4C films that have been studied previously, and discuss the significance of these results with regard to the eventual development of a hard X-ray nuclear line telescope.

Additional Information

© 2003 Society of Photo-Optical Instrumentation Engineers (SPIE). This work was funded by an SR&T grant from NASA.

Attached Files

Published - 639.pdf

Files

639.pdf

Files (870.3 kB)

Name Size Download all
md5:818dec45b2c366102f0a3e1a153b9075
870.3 kB Preview Download

Additional details

Identifiers

Eprint ID
84259
Resolver ID
CaltechAUTHORS:20180111-125339316

Funding

NASA

Dates

Created
2018-01-11
Created from EPrint's datestamp field
Updated
2021-11-15
Created from EPrint's last_modified field

Caltech Custom Metadata

Caltech groups
Space Radiation Laboratory
Series Name
Proceedings of SPIE
Series Volume or Issue Number
4851