Published May 1995 | Version public
Journal Article Open

Effective control of the error in a direct measurement of core-loss power

Abstract

Accuracy of a direct measurement of core-loss power is severely limited in many applications by the extra phase shift between the measured voltage and current. An analysis of the error is for the first time performed, which not only unfolds the hidden physical nature behind it, but also reveals a simple and effective method to control the sensitivity and hence the error. This method can also be used to satisfy a prescribed tolerance. Extensive measurements on a TDK PC40 core yield results which support the analysis.

Additional Information

© Copyright 1995 IEEE. Reprinted with permission. Manuscript received March 15, 1993; revised November 11, 1994.

Files

TANieeetm95.pdf

Files (529.9 kB)

Name Size Download all
md5:e0d9a8c7ee34e94e53af59a78ee713ce
529.9 kB Preview Download

Additional details

Identifiers

Eprint ID
10364
Resolver ID
CaltechAUTHORS:TANieeetm95

Dates

Created
2008-05-01
Created from EPrint's datestamp field
Updated
2021-11-08
Created from EPrint's last_modified field